Purifying DNA from an enzymatic reaction

From 2008.igem.org

(Difference between revisions)
 
Line 1: Line 1:
 +
{{:Team:Newcastle University/Header}}
 +
{{:Team:Newcastle University/Template:UnderTheProtocol|page-title=[[Purifying DNA from an enzymatic reaction]]}}
 +
To purify DNA from an enzymatic reaction we used the GE Healthcare illustra GFX PCR DNA and Gel Band Purification Kit, and the method outlined below is taken from their protocol manual included with the kit.  
To purify DNA from an enzymatic reaction we used the GE Healthcare illustra GFX PCR DNA and Gel Band Purification Kit, and the method outlined below is taken from their protocol manual included with the kit.  

Latest revision as of 16:02, 28 October 2008

Bugbuster-logo-red.png
Ncl uni logo.jpg


Newcastle University

GOLD MEDAL WINNER 2008

Home Team Original Aims Software Modelling Proof of Concept Brick Wet Lab Conclusions


Home >> Wet Lab >> Protocols >> Purifying DNA from an enzymatic reaction

To purify DNA from an enzymatic reaction we used the GE Healthcare illustra GFX PCR DNA and Gel Band Purification Kit, and the method outlined below is taken from their protocol manual included with the kit.

This can be found here:[1]

1) Sample Capture

  • Add 500 μl Capture buffer type 2 to up to 100 μl sample.

Note: If sample volume is greater than 100 μl, divide the sample and purify using more than one GFX MicroSpin column.

  • Mix thoroughly.
  • Place a GFX MicroSpin column into a Collection tube.

2) Sample Binding

  • Centrifuge Capture buffer type 2-sample briefly.
  • Load the Capture buffer type 2-sample mix onto the assembled GFX MicroSpin column and Collection tube.
  • Spin the assembled column and Collection tube at 16 000 × g for 30 seconds.
  • Discard the flow through. Place the GFX MicroSpin column back inside the Collection tube.

3) Wash & Dry

  • Add 500 μl Wash buffer type 1 to the GFX MicroSpin column.
  • Spin the assembled column and Collection tube at 16 000 × g for 30 seconds.
  • Discard the Collection tube and transfer the GFX MicroSpin column to a fresh DNase-free 1.5 ml microcentrifuge tube

4) Elution

  • Add 10–50 μl Elution buffer type 4 OR type 6 to the center of the membrane in the assembled GFX MicroSpin column and sample Collection tube.
  • Incubate the assembled GFX MicroSpin column and sample Collection tube at room temperature for 1 minute.
  • Spin the assembled column and sample Collection tube at 16 000 × g for 1 minute to recover the purified DNA.
  • Proceed to downstream application. Store the purified DNA at -20°C.