Team:University of Ottawa/24 July 2008

From 2008.igem.org

(Difference between revisions)
(Today in the lab)
Line 78: Line 78:
:::<li> Ran against a water control and DQ2325601 digested with EcoRI for one and a half hours on a 1% gel at 80V
:::<li> Ran against a water control and DQ2325601 digested with EcoRI for one and a half hours on a 1% gel at 80V
:::<li> One of two samples still showed desired bands following double-check. This sample was streaked onto a master plate, which was incubated at 37 C overnight, and glycerol stocked in the -80 C fridge for further use.
:::<li> One of two samples still showed desired bands following double-check. This sample was streaked onto a master plate, which was incubated at 37 C overnight, and glycerol stocked in the -80 C fridge for further use.
 +
'''Matt'''
 +
:'''Ligation Results'''
 +
::<li> A gel was run after two hours for ligation of PTP2/pSSA42 - unsuccessful.
 +
::<li> A gel was run with overnight ligation - vector and H2O controls were clean and ligation product band is slightly visible in 3:1 ratio. However there is auto ligation occuring with the vector.
 +
:'''PCR'''
 +
::<li> Dan and I decided that the initial extraction of PTP2 after PCR yielded a product that was too concentrated to be properly extracted - so I am redoing the PCR amplification with elongation time raised to 1 min 15 sec and annealing temp raised to 58 C.
 +
::<li> I will also spread the PTP2 amplification product over many different lanes on the gel so that it can be properly extracted.

Revision as of 18:41, 7 August 2008

Untitled Document

 

 


Today in the lab

Chris

Double-Check of AtCRE
  • Digested samples showing desired bands with EcoRI for one hour.
  • Ran against a water control and DQ2325601 digested with EcoRI for one and a half hours on a 1% gel at 80V
  • One of two samples still showed desired bands following double-check. This sample was streaked onto a master plate, which was incubated at 37 C overnight, and glycerol stocked in the -80 C fridge for further use.
  • Matt

    Ligation Results
  • A gel was run after two hours for ligation of PTP2/pSSA42 - unsuccessful.
  • A gel was run with overnight ligation - vector and H2O controls were clean and ligation product band is slightly visible in 3:1 ratio. However there is auto ligation occuring with the vector.
  • PCR
  • Dan and I decided that the initial extraction of PTP2 after PCR yielded a product that was too concentrated to be properly extracted - so I am redoing the PCR amplification with elongation time raised to 1 min 15 sec and annealing temp raised to 58 C.
  • I will also spread the PTP2 amplification product over many different lanes on the gel so that it can be properly extracted.