Team:Chiba/Receiver experiments

From 2008.igem.org

(Difference between revisions)
(LuxR mutants)
 
(43 intermediate revisions not shown)
Line 1: Line 1:
<html><link rel="stylesheet" href="https://2008.igem.org/wiki/index.php?title=User:Hiroki/style.css&action=raw&ctype=text/css" type="text/css" /></html>
<html><link rel="stylesheet" href="https://2008.igem.org/wiki/index.php?title=User:Hiroki/style.css&action=raw&ctype=text/css" type="text/css" /></html>
[[Image:Chiba-U.gif]]
[[Image:Chiba-U.gif]]
-
 
{| style="color:white;background-color:Maroon" cellpadding="3" cellspacing="3" border="1" bordercolor="white" width="100%" align="center"
{| style="color:white;background-color:Maroon" cellpadding="3" cellspacing="3" border="1" bordercolor="white" width="100%" align="center"
!align="center"|[[Team:Chiba|Home]]
!align="center"|[[Team:Chiba|Home]]
Line 7: Line 6:
!align="center"|[[Team:Chiba/Project|The Project]]
!align="center"|[[Team:Chiba/Project|The Project]]
!align="center"|[[Team:Chiba/Parts|Parts Submitted to the Registry]]
!align="center"|[[Team:Chiba/Parts|Parts Submitted to the Registry]]
 +
!align="center"|[[Team:Chiba/Reference|Reference]]
!align="center"|[[Team:Chiba/Notebook|Notebook]]
!align="center"|[[Team:Chiba/Notebook|Notebook]]
 +
!align="center"|[[Team:Chiba/Acknowledgements|Acknowledgements]]
|}
|}
-
{| style="border:0;width:100%;font-family:'Trebuchet MS'" cellpadding="20px" cellspacing="0"
+
==Receiver crosstalk==
-
| align="center" |
+
 
-
<span style="font-size:120%;font-weight:bold;">[[Team:Chiba/Project|Project Design]] ( [[Team:Chiba/Sender_experiments|Sender 実験]] | [[Team:Chiba/Receiver_experiments|レシーバー実験]] )  |  [[Team:Chiba/Goal|Our Goal]]</span><br>
+
===Design===
-
|}
+
[[Image:Table R chiba.gif|frame|left|Table.1 LuxR family gene]]
 +
センダーとレシーバーを元来とは異なる組み合わせにすることによって、thresholdに達する時間を遅くする。(杉山)
 +
 
 +
===Method===
 +
 
 +
===Result===
 +
 
 +
==Change Receiver's Copy Number==
 +
 
-
===LuxR/Plux mutants===
+
===Design===
-
===method===
+
レシーバーのコピーナンバーを減らすことで、thresholdに達するまでの時間を伸ばす。
 +
(小林)
-
===result===
+
===Method===
-
===AiiA Receiver===
+
*High Copy Receiver[http://partsregistry.org/Part:BBa_T9002 BBa_T9002 (AHL Reporter)]
-
[[Image:AiiA-Receiver Chiba.gif|frame|right|'''Fig.6''' AiiA Receiver]]
+
-
'''Design'''
+
[[Image:T9002.copy-number-change Chiba.gif]]
-
オートインデューサー不活性化酵素であるAiiAをレシーバー菌で発現させることにより、レシーバー菌内でのAHL濃度の増加が遅くなるため、AiiAを発現しないレシーバー菌に比べて、GFP発現が遅くなる。
 
-
'''Experiment'''
+
*Medium Copy Receiver
-
*'''Sender'''
+
-
**[http://partsregistry.org/Part:BBa_S03623 BBa_S03623 (AHL auto inucer)]
+
-
[[Image:LuxI-sender Chiba.gif]]
+
 +
[[Image:Low-copy-Receiver Chiba.gif]]
-
===method===
 
-
===result===
+
High Copy ReceiverとMedium Copy Receiverのディレイタイムはfollowing procedureによってanalyzeした。
-
*'''Receivers'''
+
#Transformed sender(Ptet-LuxI), high copy receiver(Ptet-LuxR-Plux-GFP-colE1) and Medium copy receiver(Ptet-LuxR-Plux-GFP-p15A) respectively into E coli strains(BD⊿FliC).
-
**AiiA Receiver
+
#Inoculated them independently in liquid media. Incubated at 37℃ 12h.
-
[[Image:AiiA-Receiver-genetic-circu Chiba.gif]]
+
#Inoculated again in Fresh liquid media upto about OD600=2 at 37℃
 +
#Washed sender and receivers.
 +
#Mixed them. (Sender:Receiver=1000μL:1000μL)
 +
#Incubated at 30°C.
 +
#Measured intensity of green fluorescence at regular time intervals.(Fluoroskan AscentR FL&Fluoroskan AscentR Thermo ELECTRON CORPORATION)
-
**non-AiiA Receiver
+
===Result===
-
[[Image:Non-AiiA-Receiver Chiba.gif]]
+
 +
'''>[[Team:Chiba/Project#Receiver|Back to the project page]]'''
{| style="color:white;background-color:Maroon" cellpadding="3" cellspacing="3" border="1" bordercolor="white" width="100%" align="center"
{| style="color:white;background-color:Maroon" cellpadding="3" cellspacing="3" border="1" bordercolor="white" width="100%" align="center"

Latest revision as of 19:28, 29 October 2008

Chiba-U.gif

Home The Team The Project Parts Submitted to the Registry Reference Notebook Acknowledgements

Contents

Receiver crosstalk

Design

Table.1 LuxR family gene

センダーとレシーバーを元来とは異なる組み合わせにすることによって、thresholdに達する時間を遅くする。(杉山)

Method

Result

Change Receiver's Copy Number

Design

レシーバーのコピーナンバーを減らすことで、thresholdに達するまでの時間を伸ばす。 (小林)

Method

  • High Copy Receiver[http://partsregistry.org/Part:BBa_T9002 BBa_T9002 (AHL Reporter)]

T9002.copy-number-change Chiba.gif


  • Medium Copy Receiver

Low-copy-Receiver Chiba.gif


High Copy ReceiverとMedium Copy Receiverのディレイタイムはfollowing procedureによってanalyzeした。

  1. Transformed sender(Ptet-LuxI), high copy receiver(Ptet-LuxR-Plux-GFP-colE1) and Medium copy receiver(Ptet-LuxR-Plux-GFP-p15A) respectively into E coli strains(BD⊿FliC).
  2. Inoculated them independently in liquid media. Incubated at 37℃ 12h.
  3. Inoculated again in Fresh liquid media upto about OD600=2 at 37℃
  4. Washed sender and receivers.
  5. Mixed them. (Sender:Receiver=1000μL:1000μL)
  6. Incubated at 30°C.
  7. Measured intensity of green fluorescence at regular time intervals.(Fluoroskan AscentR FL&Fluoroskan AscentR Thermo ELECTRON CORPORATION)

Result

>Back to the project page