Team:Chiba/Calendar-Home/11 October 2008

From 2008.igem.org

(Difference between revisions)
 
(6 intermediate revisions not shown)
Line 3: Line 3:
[[Team:Chiba/Calendar-Home/10 October 2008|10 October 2008 <]]|[[Team:Chiba/Calendar-Home/12 October 2008|> 12 October 2008]]
[[Team:Chiba/Calendar-Home/10 October 2008|10 October 2008 <]]|[[Team:Chiba/Calendar-Home/12 October 2008|> 12 October 2008]]
-
 
+
==Laboratory work==
-
 
+
===Team:Demo-Rs===
-
<BR>
+
~10 October
-
 
+
#Sender Wash
-
 
+
##Centrifuged 2 tubes containing([http://partsregistry.org/Part:BBa_T9002 BBa_T9002](JW1908))at 20&deg;C,3600rpm for 6min and discarded supernatant.
-
朝senderをwashして菌液10mlとLB-agar10mlを混ぜて固まらないうちにプレートに流し込む。
+
##Added 10mL LB-Amp to each tube.
-
 
+
##Repeated wash twice.
-
 
+
#Creating bacterial plates
-
receiverをニトロセルロースで写し取り、senderのプレートにはる。そこをスタートとして37℃の培養機にいれ、30分ごとにUVを当ててGFPが出ているかどうかを確認する。
+
##LB-Amp pre-cultured Sender([http://partsregistry.org/Part:BBa_S03623 BBa_S03623](JW1908)) tube(10mL) was mixed with LB-Amp-agar(50&deg;C)(10ml)to produce sender containing bacterialplate.
 +
#Lifted with nitrocellulose
 +
##Receiver([http://partsregistry.org/Part:BBa_T9002 BBa_T9002](JW1908))colony was transfered to a nitrocellulose filter and placed on each of Sender([http://partsregistry.org/Part:BBa_S03623 BBa_S03623](JW1908))containing bacterial plate and Sender-absent negative control plate (t=0).
 +
#Method to detect fluorescence
 +
##Plates cultured at 37&deg;C were exposed to UV (312nm) light once every 30 minutes to observe GFP fluorescence.

Latest revision as of 00:38, 30 October 2008

>Home | Notebook

10 October 2008 <|> 12 October 2008

Laboratory work

Team:Demo-Rs

~10 October

  1. Sender Wash
    1. Centrifuged 2 tubes containing([http://partsregistry.org/Part:BBa_T9002 BBa_T9002](JW1908))at 20°C,3600rpm for 6min and discarded supernatant.
    2. Added 10mL LB-Amp to each tube.
    3. Repeated wash twice.
  2. Creating bacterial plates
    1. LB-Amp pre-cultured Sender([http://partsregistry.org/Part:BBa_S03623 BBa_S03623](JW1908)) tube(10mL) was mixed with LB-Amp-agar(50°C)(10ml)to produce sender containing bacterialplate.
  3. Lifted with nitrocellulose
    1. Receiver([http://partsregistry.org/Part:BBa_T9002 BBa_T9002](JW1908))colony was transfered to a nitrocellulose filter and placed on each of Sender([http://partsregistry.org/Part:BBa_S03623 BBa_S03623](JW1908))containing bacterial plate and Sender-absent negative control plate (t=0).
  4. Method to detect fluorescence
    1. Plates cultured at 37°C were exposed to UV (312nm) light once every 30 minutes to observe GFP fluorescence.