* Configure Kiethley/LabVIEW to support measurement from 9 fuel cells | * Configure Kiethley/LabVIEW to support measurement from 9 fuel cells | ||
* Run test with 9 identical wt chambers to test for reproducibility of results | * Run test with 9 identical wt chambers to test for reproducibility of results | ||
+ | ** Use argon instead of nitrogen on anode side | ||
- | = | + | =First Nine-chamber Test= |
* Clean and re-build fuel cells in preparation for experiment | * Clean and re-build fuel cells in preparation for experiment | ||
+ | ** Reused cathodes, but replaced Nafion membrane and anode | ||
* Placed built fuel cells under UV light to prevent contamination | * Placed built fuel cells under UV light to prevent contamination | ||
- | |||
- | |||
- | |||
- | |||
[[Image:shaking.jpg | 600px]] | [[Image:shaking.jpg | 600px]] | ||
Line 33: | Line 31: | ||
:-Shows that shaking directly affects current production | :-Shows that shaking directly affects current production | ||
+ | |||
+ | :-Therefore, amount of gas bubbling directly affects current production | ||
+ | |||
+ | - Possible to use this as direct test for computer interface |
Latest revision as of 21:22, 29 October 2008
Goals for this week
- Finish building remainder of chambers to bring us up to a total of 9 working fuel cells
- Configure Kiethley/LabVIEW to support measurement from 9 fuel cells
- Run test with 9 identical wt chambers to test for reproducibility of results
- Use argon instead of nitrogen on anode side
First Nine-chamber Test
- Clean and re-build fuel cells in preparation for experiment
- Reused cathodes, but replaced Nafion membrane and anode
- Placed built fuel cells under UV light to prevent contamination
Variance Test with Shaking
What we did:
-Tested how much variance existed among chambers by running 9 parallel chambers with wt Shewie
-Switched nitrogen gas with argon gas on the anode side
-Shook chamber 1 manually to see the effect of shaking on current production
Results:
-Current production range was between 50-75 microAmps
-Red line (wt w/ shaking) went up to 500 microAmps when shaking vigorously
- -Shows that shaking directly affects current production
- -Therefore, amount of gas bubbling directly affects current production
- Possible to use this as direct test for computer interface