#five 10mL seed stocks of PCC6803 in BG-11 media | #five 10mL seed stocks of PCC6803 in BG-11 media | ||
#five plates smeared with 200uL PCC6803 in BG-11 media, all from old plates | #five plates smeared with 200uL PCC6803 in BG-11 media, all from old plates | ||
- | '''Hypothesis:''' Liquid Cultures of PCC6803 clump when incubated in Erlenmeyer Flasks and does not when cultured in | + | '''Hypothesis:''' Liquid Cultures of PCC6803 clump when incubated in Erlenmeyer Flasks and does not when cultured in 'box' culture flasks: Is this due to the motion of the media in different containers, the surface area of the culture, is it reproducible? |
- | # | + | #Question 1: Does the clump go back to homogeneous when placed in square culture flask? |
- | ##Took 0.5mL of a clump and placed it in 2 culture bottles | + | ##Test: Took 0.5mL of a clump and placed it in 2 square culture bottles. (1 of the bottles was fresh BG-11 media, the other was the old stock to which buffer was added today) |
- | ##Took 0.5mL of a homogeneous liquid culture and placed it in 2 culture bottles | + | ##Compare to: Took 0.5mL of a homogeneous liquid culture and placed it in 2 square culture bottles. (1 of the bottles was fresh BG-11 media, the other 1 was the old stock to which buffer was added today) |
- | # | + | #Question 2:Will previously homogeneous culture go to clump? |
##Homogeneous liquid culture placed in BG-11 media in an Erlenmeyer flask 1:10, Vfinal=50 mL | ##Homogeneous liquid culture placed in BG-11 media in an Erlenmeyer flask 1:10, Vfinal=50 mL | ||
##Homogeneous liquid culture placed in BG-11 media in an Culture flask 1:10, Vfinal=50 mL | ##Homogeneous liquid culture placed in BG-11 media in an Culture flask 1:10, Vfinal=50 mL |
Revision as of 02:56, 27 May 2008
Margaret
Made seed stocks
- five 10mL seed stocks of PCC6803 in BG-11 media
- five plates smeared with 200uL PCC6803 in BG-11 media, all from old plates
Hypothesis: Liquid Cultures of PCC6803 clump when incubated in Erlenmeyer Flasks and does not when cultured in 'box' culture flasks: Is this due to the motion of the media in different containers, the surface area of the culture, is it reproducible?
- Question 1: Does the clump go back to homogeneous when placed in square culture flask?
- Test: Took 0.5mL of a clump and placed it in 2 square culture bottles. (1 of the bottles was fresh BG-11 media, the other was the old stock to which buffer was added today)
- Compare to: Took 0.5mL of a homogeneous liquid culture and placed it in 2 square culture bottles. (1 of the bottles was fresh BG-11 media, the other 1 was the old stock to which buffer was added today)
- Question 2:Will previously homogeneous culture go to clump?
- Homogeneous liquid culture placed in BG-11 media in an Erlenmeyer flask 1:10, Vfinal=50 mL
- Homogeneous liquid culture placed in BG-11 media in an Culture flask 1:10, Vfinal=50 mL
Discussion
- What to do in the future:
- The plates are drying out too soon so we need to make them 5mm thick instead of 3mm thick.
- Get autoclave certification. We need to make media and autoclave hood materials: paper towels (?), eppendorf tubes, blocks, etc.
- Get Pictures!
- If our action is not recorded, we are doomed to either repeat the error, or fail to replicate the success.