Team:Chiba/protocol/phenotype/timedelay
From 2008.igem.org
>team chiba Internal
>return to 実験ログ
>return to protocols page
Contents |
Time-delay check(冨永)
Purpose
To Confirm that communication using non-endogenous molecules results in slower activation of receivers.
Equipments and Materials
Equipment
- shaking incubator(37°C,30°C)
- Innova 4200 Benchtop or Floor-Stackable Incubator Shaker(37°C)
- Taitec BioShaker BR-33FM(30°C,200rpm)
- 46-well plate(deep well)
- Fluoroskan Ascent 2.5(program:Ascent Software Version 2.6)
- Beckman Allegratm X-12R Centrifuga(Beckman Coulter)
Materials
- AHL(100uM)
- E.coli Culture Containing T9002
- E.coli Culture Containing plasmids you will testing
Protocol
Culturing overnight (before the testing day):
- Inoculate all cultures you will testing from gloycerol stocks into 2mL of LB-ampicillin liquid medium.
- Also inoculate a culture containing T9002 into 2mL of LB-ampicillin liquid medium.
- Incubate all cultures with shaking at 37°C(O/N).
Following day
- cultures containing T9002
- Inoculate a culture by adding 100μL of the cultures into 40mL of LB-ampicillin medium.(in a flask)
- Incubate a culture for 6-8 hours with shaking at 37°C.
- Wash
- Aliquote 10mL of the culture into 50mL four 50mL falcon tubes.
- Cultures are centrifuged at 3500rpm for 6 minutes.
- Dinspense supernatant.
- Add 10mL of new LB-ampicillin medium and resuspense with pipetting.
- aliquote 1mL of the cultures into a 48-deep well plate(deep well).
English
- cultures containing plasmids you will testing
- Inoculate cultures by adding 12.5μL of the cultures into 5mL of LB-ampicillin medium.
- Incubate cultures for 6-8 hours with shaking at 37°C.
- Wash
- Cultures are centrifuged at 3500rpm for 6 minutes.
- Dinspense supernatant.
- Add 3mL of new LB-ampicillin medium and resuspense with pipetting.
- repeat washing process twice.
- Cultures are centrifuged at 3500rpm for 6 minutes.
- Dinspense supernatant.
- Add 5mL of new LB-ampicillin medium and resuspense with pipetting.
- aliquote cultures into a 48-deep well plate(deep well).
Measurement
- Incubate testing cultures with shaking at 37°C.
- After some intervals,aliqupte 100μL of testing cultures into a 96-well plate(shallow well).
- Measure fluorescence intensity.
- conditions
- shaking(before measurement):On time = 1min,Off time = 10 sec,
- integration time = 1000ms
- Beam width:Normal Beam
- Wavelength pair = 485nm(excitation) and 527nm(emission)
return to Sender experiments details