Motility Analysis

Approach


As part of our chasis characterisation process, we have decided to model B. subtilis motility. In order to do this, the approach illustrated below was taken. The first phase of modelling involved data collection using microscopy techniques and cell tracking. Collected data was then analysed using algorithms which enabled us to extract distributions of parameters as defined in our model.

Approach.jpg
Materials

We used the Zeiss Axiovert 200 inverted microscope and Improvision Volocity acquisition software. This system offers a full incubation chamber with temperature control and a highly sensitive 1300x1000 pixel camera for fast low-light imaging. Video images are captured into memory by the system at a basal video frame rate of 16.3Hz. This can be further increased to 27.9Hz by performing x4 binning.

Method

We manually tracked motile B. subtilis, obtaining two-dimensional coordinate data points which describes by the trajectory of the cells. The open source tracking software can be found [http://rsbweb.nih.gov/ij/plugins/track/track.html here].

Data Extraction

The coordinate data obtained was then fed into algorithms to model cell trajectory and motility.


Motility Model


The following mechanical model was developed.

Mechanical Model.jpg

From the figure above, we equate the drag force and flagellum force to obtain:

Sum of Forces.JPG

Solving this first order ODE, we derive an expression for cell velocity:

Velocity.JPG, where Para 1.JPG

Solving the first order ODE for displacement, we derive an expression for cell trajectory:

Displacement.JPG

Using our fitted data, we are able to determine parameters:

Parameter.JPG

In this model, we attempt to obtain a distribution for the flagellar force, which is represented by parameter A. We assume that the medium is homogenous and the drag coefficient is constant throughout the medium, hence the distribution of flagellar force will be sufficiently be described by parameter A.


Results


The following figure shows the results of our model fitting. We have introduced a change in flagellar force at certain points of the cell trajectory so as to achieve a better fit. A maximum of two runs were allowed for each cell trajectory.

Fitted Models.jpg

The MATLAB Distribution Fitting Tool was used to model the distribution of parameter A. Parameter A was found to be exponentially distributed. The following figures describe the probability density function and cumulative density function.

Exponential Distribution for Parameter A PDF.jpg

Exponential Distribution for Parameter A CDF.jpg


Conclusion


From our model fitting process, we can see that flagellum force is exponentially distributed. Our mechanical model though simple, fits the cell trajectory data extremely well as shown in the figure above. Further work which can be done would be to utilise a movable stage to track the movement of B. subtilis over its entire run so as to obtain a distribution of other motility parameters associated running and tumbling events.