x
Setup
- Apparatus is setup as shown. An earth is needed next to the probe electrode, but not touching. They will be needed within the same solution to reduce the noise.
- Oscilloscope is set to 0.2V/div and 0.2 sec/div
- Cells containing biobrick K090002 are grown overnight in NOK with 5%(by vol.) 2M KCl added - final 100mM K+.
- Samples are then spun down in individual 1.5ml eppendorfs.
Experiment
- Resuspend cells in 200μL clean NOK and place in sample wells
- Lower probe electrode into cell solution and wait for stable reading - 1min.
- Add sample solution
Results
- With the setup above a voltage change could be observed on the oscilloscope.
- The following results were recorded by adding different amounts of 10uL glutamate to the samples.
*10uL Aspartate produced the bottom curve, showing very little recover
*5uL Glutamate gave the next curve
*10uL Glutamate gave the third curve
*20uL Glutamate gave the best recovery, reaching the highest level
x