Team:Tokyo Tech/Acrylic container

From 2008.igem.org

(Difference between revisions)
(2. Acrylic container)
(2. Acrylic container)
Line 30: Line 30:
         </tr>
         </tr>
       </table>
       </table>
-
 
+
<br><br>
<table width="100%" border="0" cellspacing="0" cellpadding="0">
<table width="100%" border="0" cellspacing="0" cellpadding="0">
         <tr>  
         <tr>  
Line 42: Line 42:
<table width="100%" border="0" cellspacing="0" cellpadding="0">
<table width="100%" border="0" cellspacing="0" cellpadding="0">
         <tr>  
         <tr>  
-
           <td class="a" width="2%"> </td>
+
           <td class="a" width="2%"> <IMG src="https://static.igem.org/mediawiki/2008/1/1b/Tech_aqulyl1.JPG
 +
" align="middle"></td>
           <td class="a">
           <td class="a">
<p class=MsoNormal>* “Plac” stands for a promoter repressed by lac protein.
<p class=MsoNormal>* “Plac” stands for a promoter repressed by lac protein.
Line 49: Line 50:
         </tr>
         </tr>
       </table>
       </table>
-
 
+
<br><br>
<table width="100%" border="0" cellspacing="0" cellpadding="0">
<table width="100%" border="0" cellspacing="0" cellpadding="0">
         <tr>  
         <tr>  
-
           <td class="a" width="3%"> </td>
+
           <td class="a" width="2%"> </td>
           <td class="a">
           <td class="a">
<p class=MsoNormal>After pressurized the container, we observed the E.coli by a fluorescence microscope. The result shows below.</p></td>
<p class=MsoNormal>After pressurized the container, we observed the E.coli by a fluorescence microscope. The result shows below.</p></td>

Revision as of 17:50, 24 October 2008

Home Construction Acrylic container Development of promoter Genetic toggle switch Parts Submitted to the Registry Result The Team Notebook


2. Acrylic container

 

We create devices for confirming pressure response of lac promoter. This is the first step of creating touch display. This device made of Acrylic glasses and has two holes (show figure). Each hole contains tubes and water. Inside tubes E. coli is cultivated. Pressure can travel to inside tubes. One hole (A) is covered with a plastic tape (show figure). Therefore the hole is pressurized.The other (B) is covered with a block made of an acrylic glass. (show figure) Therefore the hole is not pressurized by water.

 


 

E.coli type in tubes

 
 

* “Plac” stands for a promoter repressed by lac protein. On pSB6 plasmid (E.coli strain; JM109)

 


 

After pressurized the container, we observed the E.coli by a fluorescence microscope. The result shows below.