Brown: Team Resistance/14 July 2008
From 2008.igem.org
(→14 July 2008) |
(→Meeting with Professor Jerry Daniels) |
||
(3 intermediate revisions not shown) | |||
Line 3: | Line 3: | ||
==14 July 2008== | ==14 July 2008== | ||
+ | ====Update Meeting==== | ||
- | Back to lab after meeting | + | We’re ready to start running resistance tests by lysing our pVJ4 cells and measuring the change |
+ | *Last week, | ||
+ | *We have a meeting with Professor Jerry Daniels later today and Dan Ludwig to fix our apparatus and hopefully today we can run tests with it today | ||
+ | *Submitted our part (SRRz) to the registry (not the DNA yet) | ||
+ | *We re-did the lysis test with pVJ4 taking OD readings in smaller time increments (results in Kate’s notebook) and found that lysis happens with pVJ4 in 2 hours | ||
+ | *Worked on the background/application of our project and the wiki page | ||
+ | *With Dan’s help, we will install the a CD amp chip into our circuit so that we can amplify a small voltage outputted into our solution (Professor Palmore said the 5V was too much to put across solution, so we will output 2-5mV and have it amplified to give us a resistance reading in the range we have been getting | ||
+ | *Compare resistance readings of our set-up with readings from a voltmeter to test accuracy of apparatus | ||
+ | *Lyse cells in minimal media instead of LB because the ion content of minimal media is controlled and known | ||
+ | *Suggestion that we simply use OD measurements as a reporter instead of resistance measurements (implement a small laser in a chip) | ||
+ | |||
+ | ====Meeting with Professor Jerry Daniels==== | ||
+ | |||
+ | We went to his classroom/office (BH) | ||
+ | Suggestions: | ||
+ | *Try using a potentiometer instead of constantly changing comparison resistors | ||
+ | *use standard copper wire in the breadboard for the circuit and only use gold/platinum for the part of the wire that enters solution | ||
+ | *make sure to specify our labview program between single-ended and differential (under properties) | ||
+ | bipolar +/- analog outputs | ||
+ | 0→8 | ||
+ | 1→9 | ||
+ | 2→10 | ||
+ | 3→11 | ||
+ | 4→12 | ||
+ | *Use Maex to test the efficiency of the circuit (program comes with Labview) | ||
+ | *Try inputting a signal in a sawtooth-wave instead of in a sinusoidal wave | ||
+ | *To relieve strain in the wires, braid them | ||
+ | *wire everything to only one ground | ||
+ | |||
+ | AI0: 68 | ||
+ | AGND: 67 | ||
+ | |||
+ | *Daniels used a braided potentiometer and channel 1 in Maex | ||
+ | *input:5V | ||
+ | *Used an oscilloscope to test circuit→seems to work | ||
+ | *there appears to be noise in the system | ||
+ | if it’s comes to be too much, use a capacitor (low pass filter) or a lower intensity to reduce noise | ||
+ | |||
+ | Labview program | ||
+ | *use single point read | ||
+ | *while loop | ||
+ | *toggle-switch with shading | ||
+ | *numerical indicator | ||
+ | Signal amplification | ||
+ | *needed in order to keep input voltage low in order to prevent redox chemistry | ||
+ | *keep amplifier as close to cell solution as possible to reduce noise | ||
+ | *need a power supply to power amplifer (1-15 volts) | ||
+ | Lent us: | ||
+ | CD amp chip ($20) | ||
+ | Blue box (power supply) | ||
+ | |||
+ | |||
+ | |||
+ | ====Back to lab after meeting==== | ||
+ | |||
+ | worked with Labview and Maex to fix apparatus | ||
Dan came to the lab around 6pm to help me with the system | Dan came to the lab around 6pm to help me with the system |
Latest revision as of 18:58, 29 October 2008
14 July 2008Update MeetingWe’re ready to start running resistance tests by lysing our pVJ4 cells and measuring the change
Meeting with Professor Jerry DanielsWe went to his classroom/office (BH) Suggestions:
bipolar +/- analog outputs 0→8 1→9 2→10 3→11 4→12
AI0: 68 AGND: 67
if it’s comes to be too much, use a capacitor (low pass filter) or a lower intensity to reduce noise Labview program
Signal amplification
Lent us: CD amp chip ($20) Blue box (power supply)
Back to lab after meetingworked with Labview and Maex to fix apparatus Dan came to the lab around 6pm to help me with the system
Diagrams of circuits on pg __ of my (Rima’s) notebook Daniel Ludwig came to lab *helped me set up amplifier with power source Diagrams of the AD524 (CD amp chip) and circuit set-up on power supply on page__ of my (Rima’s) notebook Daniel drew simple diagram of our two resistors in series on page __ of my (Rima’s) notebook Equations that set parameters of our system: i=V/(R1+R2) V1= iR1 V2= iR2 V(input)=V(R1/[R1+R2]) With R1 being the comparison resistor and R2 being the solution of cells (or whatever is being measured)
V(input)= 1.02V Saved as “test” under Team resistance documents
However, Maex keeps switching to Differential, so Dan helped me re-wire the system according to the differential setting. To do this we wired each input with the respective input ground across from it (0→8, 1→9, 2→10, as described in meeting with Professor Daniels). Labview program
To potentially reduce noise (fluctuations)
Apparatus is now ready for testing Made 2 pVJ4 cultures for dilutions tomorrow Incubate 8:20pm |