Team:Paris/Modeling/f5

From 2008.igem.org

(Difference between revisions)
Line 1: Line 1:
-
[[Image:f5DCA.png|thumb|[[Team:Paris/Modeling/Protocol_Of_Characterisation|Characterisation Plasmid]] ]]
+
{{Paris/Menu}}
-
We have [FlhDC] = {coef<sub>flhDC</sub>}''expr(pTet)'' = {coef<sub>flhDC</sub>} &#131;1([aTc]<sub>i</sub>)
+
{{Paris/Header|Method & Algorithm : &#131;5}}
-
and [FliA] = {coef<sub>FliA</sub>}''expr(pBad)'' = {coef<sub>FliA</sub>} &#131;2([arab]<sub>i</sub>)
+
[[Image:f4DCA.png|thumb|Specific Plasmid Characterisation for &#131;5]]
 +
 
 +
We have <span style="color:#0000FF;">[''FlhDC'']<sub>''real''</sub> = {coef<sub>''flhDC''</sub>}''expr(pTet)'' = {coef<sub>flhDC</sub>} &#131;1([aTc]<sub>i</sub>)</span>
 +
and <span style="color:#0000FF;">[''FliA'']<sub>''real''</sub> = {coef<sub>''fliA''</sub>}''expr(pBad)'' = {coef<sub>''fliA''</sub>} &#131;2([arab]<sub>i</sub>)</span>
 +
 
 +
but we use <span style="color:#0000FF;">[aTc]<sub>i</sub> = Inv_&#131;1( [''FlhDC''] ) </span>
 +
and        <span style="color:#0000FF;">[arab]<sub>i</sub> = Inv_&#131;2( [''FliA''] ) </span>
So, at steady-states,
So, at steady-states,
Line 11: Line 17:
<br><br>
<br><br>
-
<center>
 
-
{|border="1" style="text-align: center"
 
-
|param
 
-
|signification
 
-
|unit
 
-
|value
 
-
|comments
 
-
|-
 
-
|[expr(pFlhDC)]
 
-
|expression rate of <br> pFlhDC '''with RBS E0032'''
 
-
|nM.min<sup>-1</sup>
 
-
|
 
-
|need for 20 mesures with well choosen values of [aTc]<sub>i</sub> <br> and for 20 mesures with well choosen values of [arab]<sub>i</sub> <br> and 5x5 measures for the relation below?
 
-
|-
 
-
|γ<sub>GFP</sub>
 
-
|dilution-degradation rate <br> of GFP(mut3b)
 
-
|min<sup>-1</sup>
 
-
|0.0198
 
-
|
 
-
|-
 
-
|[GFP]
 
-
|GFP concentration at steady-state
 
-
|nM
 
-
|
 
-
|need for 20 + 20 measures <br> and 5x5 measures for the relation below?
 
-
|-
 
-
|(''fluorescence'')
 
-
|value of the observed fluorescence
 
-
|au
 
-
|
 
-
|need for 20 + 20 measures <br> and 5x5 measures for the relation below?
 
-
|-
 
-
|''conversion''
 
-
|conversion ratio between <br> fluorescence and concentration
 
-
|nM.au<sup>-1</sup>
 
-
|(1/79.429)
 
-
|
 
-
|}
 
-
<br><br>
+
<div style="text-align: center">
 +
{{Paris/Toggle|Table|Team:Paris/Modeling/More_f5_Table}}
 +
</div>
-
{|border="1" style="text-align: center"
+
 
-
|param
+
<div style="text-align: center">
-
|signification <br> corresponding parameters in the [[Team:Paris/Modeling/Oscillations#Resulting_Equations|equations]]
+
{{Paris/Toggle|Algorithm|Team:Paris/Modeling/More_FP_Algo}}  
-
|unit
+
</div>
-
|value
+
-
|comments
+
-
|-
+
-
|β<sub>52</sub>
+
-
|production rate of FlhDC-pFliL '''with RBS E0032''' <br> β<sub>52</sub>
+
-
|nM.min<sup>-1</sup>
+
-
|
+
-
|
+
-
|-
+
-
|(K<sub>46</sub>/{coef<sub>fliA</sub>})
+
-
|activation constant of FlhDC-pFliL <br> K<sub>46</sub>
+
-
|nM
+
-
|
+
-
|
+
-
|-
+
-
|n<sub>46</sub>
+
-
|complexation order of FlhDC-pFliL <br> n<sub>46</sub>
+
-
|no dimension
+
-
|
+
-
|
+
-
|-
+
-
|β<sub>53</sub>
+
-
|production rate of FliA-pFliL '''with RBS E0032''' <br> β<sub>53</sub>
+
-
|nM.min<sup>-1</sup>
+
-
|
+
-
|
+
-
|-
+
-
|(K<sub>47</sub>/{coef<sub>omp</sub>})
+
-
|activation constant of FliA-pFliL <br> K<sub>47</sub>
+
-
|nM
+
-
|
+
-
|
+
-
|-
+
-
|n<sub>47</sub>
+
-
|complexation order of FliA-pFliL <br> n<sub>47</sub>
+
-
|no dimension
+
-
|
+
-
|
+
-
|}
+
-
</center>
+
-
<br><br>
+
Then, if we have time, we want to verify the expected relation
Then, if we have time, we want to verify the expected relation
[[Image:SumpFliL.jpg|center]]
[[Image:SumpFliL.jpg|center]]
 +
 +
<br>
 +
 +
<center>
 +
[[Team:Paris/Modeling/Implementation| <Back - to "Implementation" ]]| <br>
 +
[[Team:Paris/Modeling/Protocol_Of_Characterization| <Back - to "Protocol Of Characterization" ]]|
 +
</center>

Revision as of 14:05, 29 October 2008

Method & Algorithm : ƒ5


Specific Plasmid Characterisation for ƒ5

We have [FlhDC]real = {coefflhDC}expr(pTet) = {coefflhDC} ƒ1([aTc]i) and [FliA]real = {coeffliA}expr(pBad) = {coeffliA} ƒ2([arab]i)

but we use [aTc]i = Inv_ƒ1( [FlhDC] ) and [arab]i = Inv_ƒ2( [FliA] )

So, at steady-states,

F5.jpg




↓ Table ↑


param signification unit value comments
(fluorescence) value of the observed fluorescence au need for 20 mesures with well choosen values of [aTc]i
and for 20 mesures with well choosen values of [arab]i
and 5x5 measures for the relation below?
conversion conversion ratio between
fluorescence and concentration
↓ gives ↓
nM.au-1 (1/79.429)
[GFP] GFP concentration at steady-state nM
γGFP dilution-degradation rate
of GFP(mut3b)
↓ gives ↓
min-1 0.0198 Time Cell Division : 35 min.
ƒ5 activity of
pFliL with RBS E0032
nM.min-1



param signification
corresponding parameters in the equations
unit value comments
β24 total transcription rate of
FlhDC><pFliL with RBS E0032
β24
nM.min-1
(K2/{coeffliA}) activation constant of FlhDC><pFliL
K2
nM
n2 complexation order of FlhDC><pFliL
n2
no dimension
β25 total transcription rate of
FliA><pFliL with RBS E0032
β25
nM.min-1
(K8/{coefflhDC}) activation constant of FliA><pFliL
K8
nM
n8 complexation order of FliA><pFliL
n8
no dimension


↓ Algorithm ↑


find_ƒP

function optimal_parameters = find_FP(X_data, Y_data, initial_parameters)
% gives the 'best parameters' involved in f4, f5, f6, f7 or f8  
% with FlhDC = 0 or FliA = 0 by least-square optimisation
 
% X_data = vector of given values of [FliA]i or [FlhDC]i (experimentally
% controled)
% Y_data = vector of experimentally measured values f4, f5, f6, f7 or f8
% corresponding of the X_data
% initial_parameters = values of the parameters proposed by the literature
%                       or simply guessed
%                    = [beta, K -> (K)/(coef), n]
 
     function output = act_pProm(parameters, X_data)
         for k = 1:length(X_data)
                 output(k) = parameters(1)*hill(X_data(k), parameters(2), parameters(3));
         end
     end
 
options=optimset('LevenbergMarquardt','on','TolX',1e-10,'MaxFunEvals',1e10,'TolFun',1e-10,'MaxIter',1e4);
% options for the function lsqcurvefit
 
optimal_parameters = lsqcurvefit( @(parameters, X_data) act_pProm(parameters, X_data),...
     initial_parameters, X_data, Y_data, options );
% search for the fittest parameters, between 1/10 and 10 times the initial
% parameters
 
end

Then, if we have time, we want to verify the expected relation

SumpFliL.jpg


<Back - to "Implementation" |
<Back - to "Protocol Of Characterization" |