Team:Valencia/Project/Results

From 2008.igem.org

(Difference between revisions)
(Achievements)
Line 10: Line 10:
We have: <br>
We have: <br>
-
1.- Developed a brand new instrument: LCC (Liquid Culture Calorimeter) for real-time, high precision measurement of the internal temperature of a thermically isolated liquid culture. This instrument is a new technical standard that supports the characterization of other temperature-related BioBricks Parts or Devices. <br>
+
1.- Developed a brand new instrument: [[Team:Valencia/Project/Lab_work | '''LCC (Liquid Culture Calorimeter)''']] for real-time, high precision measurement of the internal temperature of a thermically isolated liquid culture. This instrument is a new technical standard that supports the characterization of other temperature-related BioBricks Parts or Devices. <br>
-
2.- Demonstrated, for the first time, that UCP-1 (termogenin) is, as expected, able to produce a significant increase in temperature in recombinant UCP-expressing yeasts. <br>
+
2.- Demonstrated, for the first time, that UCP-1 (termogenin) is, as expected, [[Team:Valencia/Project/Lab_work/2_experiments | '''able to produce a significant increase in temperature''']] in recombinant UCP-expressing yeasts. <br>
-
3.- Characterized four new biobricks (a UCP-expressing yeast, a control strain and two mutant strains with enhanced uncoupling activity) through temperature measurements with the LCC, as well as from relative growth data of the yeast cultures. <br>
+
3.- Characterized [[Team:Valencia/Parts | '''four new biobricks''']] (a UCP-expressing yeast, a control strain and two mutant strains with enhanced uncoupling activity) through temperature measurements with the LCC, as well as from relative growth data of the yeast cultures. <br>
4.- Outlined a new approach to Human Practices in Synthetic Biology by writing a Proposal for a Code, that includes a novel concept: concentric ethical units, that might be very useful not only for the Hot Yeast Project but also for any Synthetic Biology research. <br>
4.- Outlined a new approach to Human Practices in Synthetic Biology by writing a Proposal for a Code, that includes a novel concept: concentric ethical units, that might be very useful not only for the Hot Yeast Project but also for any Synthetic Biology research. <br>

Revision as of 17:50, 28 October 2008



Achievements

We have:
1.- Developed a brand new instrument: LCC (Liquid Culture Calorimeter) for real-time, high precision measurement of the internal temperature of a thermically isolated liquid culture. This instrument is a new technical standard that supports the characterization of other temperature-related BioBricks Parts or Devices.
2.- Demonstrated, for the first time, that UCP-1 (termogenin) is, as expected, able to produce a significant increase in temperature in recombinant UCP-expressing yeasts.
3.- Characterized four new biobricks (a UCP-expressing yeast, a control strain and two mutant strains with enhanced uncoupling activity) through temperature measurements with the LCC, as well as from relative growth data of the yeast cultures.
4.- Outlined a new approach to Human Practices in Synthetic Biology by writing a Proposal for a Code, that includes a novel concept: concentric ethical units, that might be very useful not only for the Hot Yeast Project but also for any Synthetic Biology research.



3.Modeling << Results