Fuel Cell Development

Motivation

The broad goal of our project was to engineer s. Odenisis to produce a detectable change in electric current in response to some environmental stimulus. In order to observe such a reaction, our first task was to design an environment capable of housing bacteria and measuring current production.

Solution - Microbial Fuel Cells

Background

Microbial fuel cells (MFCs) are devices that use bacteria as the catalysts to oxidize organic and inorganic matter and generate current <ref></ref>. The principle behind these devices is to physically separate an oxidation reaction from a reduction reaction while providing a path for electrons to travel between them. File:MFCsw1.jpg

Context

Design Goal

Functional description

The final product is a complete system capable of introducing separate strains of bacteria to multiple different environments while simultaneously measuring and recording current readings from each. The experimenter specifies the number of bacteria/environment combinations to be run, as well as the initial conditions for each. Data collection and storage is automated, with a computer displaying live current readings and graphing historical current levels. The experimenter can change the conditions of any fuel cell throughout the course of the experiment without affecting other fuel cells. The fuel cells themselves are stand-alone, capable of being treated as individual circuit components.

Specifications

  • automated

Some experiments can last several days. Measurements must be automated to allow for overnight observation.

  • anaerobic/aerobic

s. Odenisis only oxidizes substrates in anaerobic environments. The chamber housing the bacteria must be oxygen free and airtight.

  • sterile

Fuel cells must be capable of being sterilized to prevent contamination

  • reproducible

Individual fuel cells must be similar enough to produce consistent results.

  • accessible

Experimenters must have access to the bacterial environment.


Approach

Decomposition into components

Construction of the system was broken down into three distinct parts. The most important components were the fuel cells themselves. Once these devices were built, a measurement system was constructed to sample current readings from each simultaneously. Software was developed to orchestrate these readings, recording and displaying them in real time.

Component descriptions and approaches

Fuel Cells

Measurement

We required that our measurement system be automated and capable of monitoring multiple fuel cells at once. Our original goal was to measure and compare output current levels between separate fuel cell environments. We choose to use current as the measured variable since previous studies in s. Onedisis and mutants gave us reasonable expectation values of the current magnitudes we would observe. As these reported current levels were on the order of microamps for similarly sized systems, we decided to purchase a high throughput commercial digital multimeter to achieve the desired resolution. Finding a multiplexed system with large quantities of current channels proved difficult, and we adapted our schematic to measure voltage and resistance and then calculate current.

Our final product choice was the Keithley 2700 with a Keithley 7700 multiplexer accessory. This configuration provided 100 nA current resolution while allowing up to 20 devices to be sampled from at once.

We choose to use 470 Ohms as our resistance connecting the anode and cathode of each fuel cell. This choice was based on several considerations. We measured the resistance path from the surface of an anode to the surface of a cathode and found that it ranged from 5-10 Ohms. Our resistance had to be large enough that voltage drops across this internal resistance did not significantly affect the measured voltage drop across our external resistor. We also measured the resistance of the path from anode to cathode through the fuel cells media and membrane. This resistance was highly variable but typically ranged from 15K to 25K. Our external resistance had to be low enough that the vast majority of freed electrons traveled externally rather than through this variable media/membrane path.

Software

LV block1.pngLV block2.png

LV vi1.pngLV vi2.png