Brown: Team Resistance/22 October 2008
From 2008.igem.org
22 October 2008LigationpVJ4 lysis cassette and S105 lysis cassette into standard biobrick vector plasmid pSB1AK3 at EcoRI and SpeI
2.62ul S105
Transformation
Conductance testMeasuring conductance change and optical density change in parallel Set up two cultures of the pVJ4 plasmid
Because the cells grew during the experiment into stationary phase, the lysis seems to take much longer than usual. We measured conductivity and optical density of solutions every 15 minutes. Initially we had tried leaving the conductivity probe in the solution of cells, allowing the probe to take continuous readings as the cells lysed in solution. However, the probe does not seem suited to this function. It is recommended that probes be cleaned between every reading, so we are rinsing the probes with milli-q water and drying them with compressed gas between every reading. Conductivity 1: solution with ara Conductivity 2: solution without ara
|