Team:KULeuven/Project

From 2008.igem.org

(Difference between revisions)
(A bacterial drug delivery system)
Line 1: Line 1:
{{:Team:KULeuven/Tools/Header}}
{{:Team:KULeuven/Tools/Header}}
-
__NOTOC__
+
'''figuur ideetje: tekening van een potje pillen met een plakker erop “Dr. coli”.'''
-
== Dr. Coli: A bacterial drug delivery system ==
+
==Dr. Coli,  the bacterial drug delivery system==
-
Our team works on '''a bacterial drug delivery system''', for instance for the production of a peptide such as vasoactive intestinal peptide as a potential treatment for Crohn's disease. The bacterial drug delivery systems will have several advantages over classical drugs. These are (a) the bacterium will produce the exact amount of drug necessary for each individual by means of an indirect feedback control mechanism, (b) the bacterium will die upon a long symptomless period and (c) a possible development towards drugs being taken up in the bloodstream. The elaboration of such a system in a couple of months is, however, not viable. Therefore, we have decided in favour of constructing something more like a scaffolding, a proof of concept, that uses dummy in- and output and leaves room for case-dependent interpretation. Crohn's disease is, for us, only an example, rather than a limitation.
+
<div style="float:right">[[Image:drcoli.jpg|330px]]</div>
 +
Our team’s project is Dr. Coli, an E. coli bacterium that produces a drug when and where it is needed in the human body. It does this in an intelligent way, such that the drug production meets the individual patient’s needs. And when the patient is cured, Dr. Coli eliminates itself from the body. To achieve this, a molecular timer registers the time since the last disease signal sensed. Then after a certain time, Dr. Coli self-destructs. However, when the disease flares up again – above a certain noise level - the timer is reset and new drug is produced. Finally, Dr. Coli's timer will not start counting during production, thanks to its disease-memory.
-
A dummy '''input''' has been found in a light-sensing device. This is an easy-to-use system, that allows fast switching between input signals 0, noise or 1. The dummy '''output''' signal is, for more or less the same reasons, expression of a fluorescent protein. Its signal is easy to follow in time and intensity, in a non-invasive way. This input-output line is the main backbone of the project. However, without decent control, this system is worthless. First, the project includes a way of '''filtering''' noise out of the input signal. Secondly, we want the system to shut down once the infection has been overcome. Therefore, an '''inverter''', a '''clock''' and a '''cell death''' mechanism have been placed in cascade. That way, when no input signal is present, the inverter makes sure a clock starts and keeps ticking, eventually leading to cell death after some time. And thirdly, it is interesting to be able to shut down and '''reset''' the clock upon renewed presence of input signal to overcome a phase of latently present input signal. The quick-witted scientist will of course notice that this system is doomed to fail, as all cells will die on their own. That is why the fourth and last control mechanism is a '''memory''' device. This stable switch is activated by the first input signal, and remains in a set ''ON'' state for the rest of its life. Only in this ''ON'' state, the clock can start ticking. These control mechanisms are very much dependent on kinetic and other constants. Therefore, proper '''modeling''' of this system is indispensable. In a later stadium, '''data analysis''' will prove its function in fine-tuning the model. We hope that these interactions between experiments in vitro and in silico will lead us to decent results.
+
Dr. Coli thus has several advantages over classical drugs, and, if proven successful, could have many medical applications. One example could be the delivery of a vasoactive intestinal peptide as a potential treatment for Crohn's disease.
 +
 
 +
Within the time frame of the iGEM competition, we aim at delivering a proof of concept of Dr. Coli. For the input and output of the system, i.e. sensing the disease signal and producing the appropriate amount of drug, we use a dummy input-output system. The most important assets of our proof of concept are the different control mechanisms. Since these are very much dependent on kinetic and other constants, Dr. Coli heavily relies on proper [https://2008.igem.org/Team:KULeuven/Model/Overview '''modeling'''].
 +
 
 +
==Essential aspects of Dr. Coli==
 +
(more details can be found '''link''')
 +
 
 +
===Dr. Coli delivers drugs ''in situ''===
 +
[[Image:pictogram_input.png|40px|left]]
 +
[[Image:pictogram_output.png|40px|left]]
 +
 
 +
Dr. Coli produces a drug when it senses a certain disease signal in the human body. In our project, we replaced the input disease marker by a dummy light [https://2008.igem.org/Team:KULeuven/Project/Input '''input''']. The proportional [https://2008.igem.org/Team:KULeuven/Project/Output '''output'''] drug production is mimicked with a fluorescent protein.
 +
 
 +
===Dr. Coli self-destructs===
 +
[[Image:pictogram_filter.png|40px|left]]
 +
[[Image:pictogram_inverter.png|40px|left]]
 +
[[Image:pictogram_reset.png|40px|left]]
 +
[[Image:pictogram_celldeath.png|40px|left]]
 +
 
 +
When the patient is cured, Dr. Coli is no longer needed and will eliminate itself from its host. Therefore, we placed an [https://2008.igem.org/Team:KULeuven/Project/Inverter '''inverter'''], a molecular timer and a [https://2008.igem.org/Team:KULeuven/Project/CellDeath '''cell death'''] mechanism in cascade. When no input signal is present, the inverter initiates the molecular timer, eventually leading to cell death. Upon renewed presence of the disease signal, the molecular timer is [https://2008.igem.org/Team:KULeuven/Project/Reset '''reset''']. A [https://2008.igem.org/Team:KULeuven/Project/Filter '''filter'''], finally, ensures that the timer is not reset when only “noisy” disease signals  are sensed.
 +
 
 +
===Dr. Coli in production===
 +
[[Image:pictogram_memory.png|40px|left]]
 +
 
 +
To enable the production of Dr. Coli without it self-destructing, we included a [https://2008.igem.org/Team:KULeuven/Project/Memory '''memory'''] device. This is a stable switch that is activated by the first input signal. Only from then on, the clock can start ticking towards cell death.

Revision as of 14:37, 1 August 2008

  dock/undock dropdown  

figuur ideetje: tekening van een potje pillen met een plakker erop “Dr. coli”.

Contents

Dr. Coli, the bacterial drug delivery system

Drcoli.jpg

Our team’s project is Dr. Coli, an E. coli bacterium that produces a drug when and where it is needed in the human body. It does this in an intelligent way, such that the drug production meets the individual patient’s needs. And when the patient is cured, Dr. Coli eliminates itself from the body. To achieve this, a molecular timer registers the time since the last disease signal sensed. Then after a certain time, Dr. Coli self-destructs. However, when the disease flares up again – above a certain noise level - the timer is reset and new drug is produced. Finally, Dr. Coli's timer will not start counting during production, thanks to its disease-memory.

Dr. Coli thus has several advantages over classical drugs, and, if proven successful, could have many medical applications. One example could be the delivery of a vasoactive intestinal peptide as a potential treatment for Crohn's disease.

Within the time frame of the iGEM competition, we aim at delivering a proof of concept of Dr. Coli. For the input and output of the system, i.e. sensing the disease signal and producing the appropriate amount of drug, we use a dummy input-output system. The most important assets of our proof of concept are the different control mechanisms. Since these are very much dependent on kinetic and other constants, Dr. Coli heavily relies on proper modeling.

Essential aspects of Dr. Coli

(more details can be found link)

Dr. Coli delivers drugs in situ

Pictogram input.png
Pictogram output.png

Dr. Coli produces a drug when it senses a certain disease signal in the human body. In our project, we replaced the input disease marker by a dummy light input. The proportional output drug production is mimicked with a fluorescent protein.

Dr. Coli self-destructs

Pictogram filter.png
Pictogram inverter.png
Pictogram reset.png
Pictogram celldeath.png

When the patient is cured, Dr. Coli is no longer needed and will eliminate itself from its host. Therefore, we placed an inverter, a molecular timer and a cell death mechanism in cascade. When no input signal is present, the inverter initiates the molecular timer, eventually leading to cell death. Upon renewed presence of the disease signal, the molecular timer is reset. A filter, finally, ensures that the timer is not reset when only “noisy” disease signals are sensed.

Dr. Coli in production

Pictogram memory.png

To enable the production of Dr. Coli without it self-destructing, we included a memory device. This is a stable switch that is activated by the first input signal. Only from then on, the clock can start ticking towards cell death.