Team:KULeuven/1 September 2008

From 2008.igem.org

(Difference between revisions)
(Wet Lab)
m (Wet Lab)
Line 6: Line 6:
* We tried to add the second part of the UmuD tag with the 91bp-primer. We had very sharp and extremely beautiful bands, but they seemed three times too long: FAIL. This will be done again tomorrow, with primers 2.1 and 2.2.
* We tried to add the second part of the UmuD tag with the 91bp-primer. We had very sharp and extremely beautiful bands, but they seemed three times too long: FAIL. This will be done again tomorrow, with primers 2.1 and 2.2.
* The antisense LuxI PCR resulted in a smear: FAIL again. To be done again tomorrow.
* The antisense LuxI PCR resulted in a smear: FAIL again. To be done again tomorrow.
-
* We MiniPrepped the ligations we streaked out yesterday and part R1052 and R0040. It's the second time we MiniPrep R1052 and the concentrations was two times very low. The registry show that there are a few problems with this part.
+
* We MiniPrepped the ligations we streaked out yesterday and part R1052 and R0040. It's the second time we MiniPrep R1052 and the concentrations was two times very low. The registry shows that there are a few problems with this part.
* We did a PCR to test the ligations.
* We did a PCR to test the ligations.
* We made some digests: C0056 and C0061 with ''Spe''I and ''Pst''I and R0040 with ''Spe''I and ''Eco''RI. We couldn't see R0040 on gel and C0056 seemed to be too big, only C0061 was ok. We purified C0061 and C0056.  
* We made some digests: C0056 and C0061 with ''Spe''I and ''Pst''I and R0040 with ''Spe''I and ''Eco''RI. We couldn't see R0040 on gel and C0056 seemed to be too big, only C0061 was ok. We purified C0061 and C0056.  

Revision as of 19:41, 1 September 2008

  dock/undock dropdown  

Contents

Lab Work

Wet Lab

  • We tried to add the second part of the UmuD tag with the 91bp-primer. We had very sharp and extremely beautiful bands, but they seemed three times too long: FAIL. This will be done again tomorrow, with primers 2.1 and 2.2.
  • The antisense LuxI PCR resulted in a smear: FAIL again. To be done again tomorrow.
  • We MiniPrepped the ligations we streaked out yesterday and part R1052 and R0040. It's the second time we MiniPrep R1052 and the concentrations was two times very low. The registry shows that there are a few problems with this part.
  • We did a PCR to test the ligations.
  • We made some digests: C0056 and C0061 with SpeI and PstI and R0040 with SpeI and EcoRI. We couldn't see R0040 on gel and C0056 seemed to be too big, only C0061 was ok. We purified C0061 and C0056.
  • We made a ligation of C0061+B0015 (cut with PstI instead of EcoRI).

Dry Lab

Modeling

Wiki

Remarks

<< return to notebook return to homepage >>
< previous friday ← yesterday tomorrow → next monday >