Team:TUDelft/Temperature testing

From 2008.igem.org

(Difference between revisions)
(Controls)
(Controls)
Line 98: Line 98:
|}
|}
</div>
</div>
 +
<br />
==Practical Analysis==
==Practical Analysis==

Revision as of 14:13, 29 October 2008

Contents

Testing

Introduction

To test the functionality of our RNA-thermometer, we will need a reporter to see whether different temperatures give different translation. Assuming the system is not an on/off switch system, we will need a reporter which we can quantify. After some discussion with our advisors and some people from the Biotechnology Department, we decided luciferase would be the best system to use as a reporter, as it can be quantified. As a negative control for our RNA-thermometer, we would need a luciferase without a RNA-thermometer in front of it. Using the activity of this construct, we would then be able to calculate the normalized activity of the construct including our RNA-thermometer, as displayed in graph 1.

TUDelft negativecontrol.png

Graph 1: Effect of temperature on normalized expression of Luciferase behind a thermosensitive promoter.

Thermosensitive constructs

We will use the following construct, being the parts as mentioned in table 1. We have designed various thermo sensitive sequences to obtain thermometer RNA allowing translation at different temperatures and to see if we can find trends in effects of these altered sequences on the overall working of the RNA. These specifications can also be found in table 1.

TUDelft Compositethermo.jpg
Table 1: Composite parts with thermosensitive region
Expected T (°C) Source Promoter RNA-thermo + RBS Reporter 2xTerminator
42 ROSE R0080 K115001 J52008 B0015
37 FourU R0080 K115002 J52008 B0015
37 PrfA R0080 K115003 J52008 B0015
42 ROSE R0080 K115008 J52008 B0015
37 FourU R0080 K115009 J52008 B0015
27 ROSE R0080 K115016 J52008 B0015
32 ROSE R0080 K115017 J52008 B0015
37 ROSE R0080 K115020 J52008 B0015


Controls

As we want to calculate normalized activities, we will also require a negative control, without the thermometer region. This control will require a normal RBS instead. Although the RBS of the thermo sensitive RNAs is not equal to this, it is possible to correct for this mathematically. This is visible by the constant level of the thermosensitive construct above 42oC in graph 1. The construct can be found in table 2.

TUDelft compositecontrol.jpg
Table 2: Composite parts with thermosensitive region
Promoter RBS Reporter 2xTerminator
R0080 B0034 J52008 B0015


Practical Analysis

The protocol for the validation will be as follows:

  • Grow culture without induction.
  • Split cultures into different temperatures and induce promoter.
  • Grow for 3 hours.
  • Perform luciferase assay by use of a kit.

It is important to note that because the growing speed of colonies is greatly influenced by temperature, and thus also the production of mRNA/protein, the activity at each temperature has to be normalized by a negative control grown at the same temperature.

We've displayed schematically what we would expect to see in luciferase activity in table 3.

Table 3: Schematic luciferase expression
ConstructInduced20oC37oC
Normal RBS Yes + +
Thermosensitive RBS Yes - +
Thermosensitive RBS No - -