Team:Paris/July 30
From 2008.igem.org
(Difference between revisions)
(→Analysis of yesterday DNA digestion) |
(→Analysis of yesterday DNA digestion) |
||
Line 94: | Line 94: | ||
! rowspan="1"| SpeI | ! rowspan="1"| SpeI | ||
! rowspan="1"| FI | ! rowspan="1"| FI | ||
- | ! rowspan="1"| 746 | + | ! rowspan="1"| 746 bp |
! rowspan="1"| | ! rowspan="1"| | ||
! rowspan="1"| 0 (failed) | ! rowspan="1"| 0 (failed) | ||
Line 105: | Line 105: | ||
! rowspan="1"| PstI | ! rowspan="1"| PstI | ||
! rowspan="1"| BI | ! rowspan="1"| BI | ||
- | ! rowspan="1"| 745 | + | ! rowspan="1"| 745 bp |
- | ! rowspan="1"| | + | ! rowspan="1"| 700 bp |
- | ! rowspan="1"| | + | ! rowspan="1"| 2 |
! rowspan="1"| 2 & 3 | ! rowspan="1"| 2 & 3 | ||
|- | |- | ||
Line 116: | Line 116: | ||
! rowspan="1"| SpeI | ! rowspan="1"| SpeI | ||
! rowspan="1"| FI | ! rowspan="1"| FI | ||
- | ! rowspan="1"| 746 | + | ! rowspan="1"| 746 bp |
- | ! rowspan="1"| | + | ! rowspan="1"| 600 bp |
- | ! rowspan="1"| | + | ! rowspan="1"| 10 |
! rowspan="1"| 16 | ! rowspan="1"| 16 | ||
|- | |- | ||
Line 127: | Line 127: | ||
! rowspan="1"|XbaI | ! rowspan="1"|XbaI | ||
! rowspan="1"|FV | ! rowspan="1"|FV | ||
- | ! rowspan="1"| 2079 | + | ! rowspan="1"| 2079 bp |
- | ! rowspan="1"| | + | ! rowspan="1"| 2000 bp |
- | ! rowspan="1"| | + | ! rowspan="1"| 8 |
! rowspan="1"| 6 & 7 | ! rowspan="1"| 6 & 7 | ||
|- | |- | ||
Line 138: | Line 138: | ||
! rowspan="1"|PstI | ! rowspan="1"|PstI | ||
! rowspan="1"|BV | ! rowspan="1"|BV | ||
- | ! rowspan="1"| 2080 | + | ! rowspan="1"| 2080 bp |
- | ! rowspan="1"| | + | ! rowspan="1"| 2000 bp |
- | ! rowspan="1"| | + | ! rowspan="1"| 8 |
! rowspan="1"| 8 & 9 | ! rowspan="1"| 8 & 9 | ||
|} | |} |
Revision as of 16:58, 4 August 2008
Analysis of yesterday DNA digestionThe digested DNA of yesterday was analysed one more time by electrophoresis on a 0.8% agarose gel (about 30 minutes at 100 W). The ladder used was the 1 kb DNA ladder (New England Biolabs). 5 µL of each sample with 1 µL of loading dye were loaded.
Results : Each of the samples was succesfully digested and purified except for the sample D108. It seems that the QIAprep columms (from the QIAGEN Minipreps kit) can be used instead of the QIAquick columms (for DNA Gel Extraction). |